该文从双相流动的基本原理出发,分析导出了核电站汽水分离再热器疏水回路中疏水控制段的设计、计算方法.该方法适合各类双相绝热流动管系的设计和计算.
This paper derived the method of design and calculation of drain control-ler of moisture separator reheater(MSR)with the theory of two-phase flow.This method can be used to pipes of two-phase adiabatic flow.