期刊文献+

电阻环束流探测器的标定 被引量:15

Improvement on the accuracy of beam bugs in linear induction accelerator
下载PDF
导出
摘要 电阻环探测技术是一种成熟、实用的在线测试束流技术 ,它能给出束流的大小和束流质心的位置。在即将投入使用的 2 0 Me V直线感应加速器中 ,该技术将作为一种精确的束流诊断手段。为此设计了一套精密的束流模拟和电阻环标定装置 ,其束流位置的定位精度达到 0 .0 2 mm,以之对精心设计的电阻环进行标定。标定的结果表明电阻环对束流质心位置的测试精度达到 0 .5 mm,经标定后的束位置拟合值绝对误差不大于 0 .2 mm。 In linear induction accelerator the resistive wall monitors kown as 'beam bugs' have been used as essential diagnostics of beam current and location. This paper presents a new method that can improve the accuracy of these beam bugs used for beam position measurements. With a fine beam simulation set, this method locates the beam position with an accuracy of 0.02mm and thus can scale the beam bugs very well. Experiment results prove that the precision of beam position measurements can reach submillimeter degree.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2002年第1期151-155,共5页 High Power Laser and Particle Beams
基金 国防科技基础研究资助课题
关键词 直线感应加速器 电阻环探测 束流模拟 束流位置 标定 linear induction accelerator beam bugs beam simulation beam position
  • 相关文献

参考文献4

二级参考文献4

  • 1程念安.脉冲强流电子束的发射度测量[J].强激光与粒子束,1989,1(3):241-247. 被引量:5
  • 2麦纬麟.光学传递函数及其数理基础[M].北京:国防工业出版社,1979..
  • 3戴光森,10MeV直流感应加速器会议文集,1994年
  • 4麦纬麟,光学传递函数及其数理基础,1979年

共引文献23

同被引文献76

引证文献15

二级引证文献30