摘要
对湿式冷却塔配水系统的水分布不均现象 ,提出了水分布均匀度系数的概念。利用数值计算实现了配水不均对冷却塔性能影响的定量计算 。
The concept of water distribution uniformity coefficient has been put forward for the non-uniform water distribution in the wet cooling tower's water distribution system. The title quantitative calculation was carried out by using numerical computation, providing a quantitative method for diagnosing economic aspects of a cooling tower in operation.
出处
《热力发电》
CAS
北大核心
2001年第6期19-22,共4页
Thermal Power Generation