摘要
以中频高压变压器动态过程理论计算为基础 ,分析了变压器分布参数对驱动回路电流的影响规律 ,得出了适当增加变压器漏电感和减小线圈分布电容能有效减小驱动回路电流的结论 。
The theory computation is performed to analyze transient in the middle frequency high voltage transformer. Based on the analysis results, the influence of distribution parameters of transformer on the current of the driving circuit is studied. The results show that increasing leak inductor and reducing distribution capacitance can reduce current of the driving circuit.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2001年第6期28-30,共3页
High Voltage Engineering