压缩机中间冷却器的改造及其节能效果分析 被引量:12

Energy-saving Effect of Reforming Mid-cooler of Compressor
下载PDF
导出
摘要 对活塞式往复压缩机中间冷却器进行改造 ,采用不锈钢波纹管代替壳管式换热器中的直管 ,并进行了实际运行测试和节能效果的分析。波纹管换热器的天然气出口温度能够达到甚至低于压缩机的设计值 ,换热效率比列管换热器高 61% ,压缩机的操作正常平稳 ,维护工作量大大降低 ,达到长周期运行的目的。 For the mid-cooler of the piston reciprocating campressor, with its heat-transfer tubes(general) replaced by stainless steel bellows tubes, its operation data are measured after the reform, and its energy-saving effect is analyzed. The outlet temperature of natural gas of the bellows mid-cooler can reach to or even lower than the design value for the compressor, and the heat exchanger efficiency of the bellows increases by 61 % than that of original one-the shell-and-tube heat exchanger. The compressors operates stablly and normally, and be able to run for long period.
出处 《煤气与热力》 2001年第6期505-506,共2页 Gas & Heat
关键词 压缩机 换热器 波纹管换热器 节能 compressor heat exchanger bellows tube heat exchanger
  • 相关文献

参考文献2

  • 1西安交通大学管道振动科研小组.往复式压缩机管系气柱固有频率的计算与实验研究[J].西安交通大学学报,1976,(3):37-39.
  • 2《化工厂机械手册》编辑委员会.化工厂机械手册[M].北京:化学工业出版社,1989.