通过分析 135系列柴油机发电机组的TLG1 3励磁自动调压原理 ,总结出了检测和排除“自动”状态下发电机不建电、电压过高、电压波动和电压偏低故障的简捷方法。
The fundamental of the automatic voltage adjusting system us ing the TLG 1-3 type magnetic regulator for the 135-series of diesel generating set were a n alyzed.The simple and convenient methods diagnosing and removing the failure of non-voltage?higher voltage?lower voltage and voltage waving were presented un der automatic condition.