期刊文献+

聚合氯化铝中铅测定的改进 被引量:1

Improvement of the method for Determination of pb Contained in PAC
下载PDF
导出
摘要 为了得到更高的回收率及精确度 ,使用石墨炉检测水处理剂聚合氯化铝中铅含量 ,且在样品中加入基体改进剂及信号稳定剂。 In order to gain higher recovery rate and accuracy, atomization in graphite tube furnace was used in determination of lead in water treatment chemicals-PAC, matrix modifier and signal stabilizer were added to the sample. It was proved that this measure gave better determination results.
出处 《净水技术》 CAS 2001年第3期34-37,共4页 Water Purification Technology
关键词 聚合氯化铝 石墨炉 基体改进剂 信号稳定剂 测定 水处理剂 poly aluminium chloride atomization in graphite tube furnace matrix modifier signal stabilizer
  • 相关文献

参考文献3

  • 1[1]"Direct Determination of Lead Airborne Particulates by Nonflame Atomic Absorption” L.P. Matousek and K.G.Brodie
  • 2[2]"The Measurement of Lead in Food Products by Graphite Furnace AA and Spectr AA 40” K.Brodie Varian Instrument at Work
  • 3[3]"Effect of Anions on Atomization Temperature in Furnace Atomic Absorption” E.J. Czobik and J. P. Matousek

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部