摘要
采用化学元素分析、金相实验、机械性能试验等分析手段对石家庄热电厂 # 13炉屏过高温段爆管进行分析 。
Through chemical elements analysis, metallographic test, mechanical performance tests and other tests, it is believed that the blast of platen superheater of boiler No. 13 in Shijiazhuang Co-generation Power Plant is due to common effects of long term overheating and defects in original tubes.
出处
《河北电力技术》
2001年第6期29-31,共3页
Hebei Electric Power