摘要 采用钢筋混凝土有限元法,分析某船闸的裂缝成因、危害和加固措施.计算结果表明,裂缝是由于结构未配置温度钢筋,由寒潮作用引起的.因此,即使在气候温暖的南方,大体积(或尺寸较大)混凝土结构也应配置温度钢筋.同时分析表明,此结构采用拼缝盖梁加固是可行的、且经济方便.实践证明,钢筋混凝土有限元法是分析非杆系结构受力过程的一种有效方法. In the paper,the reinforced concrete FEM is used to analyze the causes and detriment of cracks in a lock,and improvement measures of the structure.The numerical results show that the cracks are caused by cold wave by lack of temperature reinforcements in the structure.Consequently,temperature reinforcements should be arranged in mass con-crete structures,even in the warm south areas.The results also show it is effective and convenient for structure to be improved using reinforced concrete beams by which the cracks can be closed.It is proved that reinforced concrete FEM is an ef-fective way for non-linear analysis of the mass reinforced concrete structure through the practice in the paper.
作者 汪基伟
出处 《水利水电技术》 CSCD 北大核心 2001年第9期5-7,9,共4页 Water Resources and Hydropower Engineering
关键词 钢筋混凝土有限元法 船闸 裂缝成因 加固 温度裂缝 温度钢筋 拼缝盖梁 reinforced concrete FEM lock temperature crack temperature reinforcement
  • 相关文献

参考文献3

二级参考文献15

  • 1揽生瑞,过镇海.定侧压下混凝土二轴受压变形特性的试验研究[J].土木工程学报,1996,29(2):28-36. 被引量:10
  • 2吴胜兴,河海大学学报,1998年,26卷,2期,21页
  • 3团体著者,DL/T5057-1996水工混凝土结构设计规范,1996年,188页
  • 4周氐,现代钢筋混凝土基本理论,1989年,345页
  • 5朱伯芳,水利学报,1983年,5期,40页
  • 6团体著者,SDJ20-78水工钢筋混凝土结构设计规范,1979年
  • 7汪基伟,河海大学学报,1998年,4期
  • 8汪基伟,水利电技术,1998年,8期
  • 9汪基伟,水利水运科学研究,1998年,4期
  • 10电力工业部西北勘测设计研究院,水工混凝土结构设计规范(DL/T5057-1996),1996年,188页