期刊文献+

对金属烤瓷修复体的金属底层进行不同处理后的扫描电镜观察 被引量:3

Scanning electron microscopic observation on changes of metallic base with different treatment in PFM
下载PDF
导出
摘要 目的 通过扫描电镜观察金属烤瓷修复体的金属底层经过不同处理后的结构及化学变化。方法 金属表面进行失晶、喷砂、砂石磨光、抛光等不同处理后用扫描电镜观察。结果 在金属表面有四种类型的结构形成 ,经过失晶处理后的金属表面形成大量空穴和倒凹状结构 ,同时元素增加及含量也增加。分布也有明显变化。经喷砂的金属表面 ,只形成大量的凹凸不平的粗糙结构 ,凹陷深度小于失晶法 ,元素增加及含量都较上述减少。砂石磨光的金属表面仅出现线状浅沟纹结构。抛光的金属表面平坦 ,无结构改变。结论 失晶能提供金瓷的机械性结合及化学结合的表面结构 ,提高金瓷结合强度。后两者均不利于金瓷的结合固位。 Objective To observe the structure and element changes of the metallic base with different treatment in PFM.Methods After decrystallizing and blasting,burnishing and polishing,the metallic surface was with scanning electron microscopy.Results There were four kinds of struture formed in the surface of the metal.Plenty of carities and undercuts formed in the metallic surface and elements' kinds and content increased after decrystallization.Plenty of concave and convex struture formed,kinds of elements increased but its content decreased after sand blasting.There was only linear and striated structure formed after burnishing.Surface of metal was smooth without changes after polishing.Conclusion In contrast with the other methods,decrystallizing is more benificial to mechanical and chemical combination of porcelain and metal.
出处 《现代口腔医学杂志》 CAS CSCD 2002年第1期30-31,共2页 Journal of Modern Stomatology
基金 吉林省科委资助项目 ( 970 32 1)
关键词 金属瓷 扫描电镜 失晶体 Porcelain fused to metal Scanning electron microscopy Decrystallization
  • 相关文献

参考文献1

共引文献5

同被引文献20

  • 1钱冬冬.金属表面处理对金-瓷结合强度的影响[J].口腔材料器械杂志,1996,5(4):161-163. 被引量:6
  • 2[1]Derek W.Jones, C.Chem. A brief overiew of cental ceramics [J] .J Can Dent Assoc,1998,64(9):648~650
  • 3[2]Donovan T,Prince J.An analysis of margin configurations for metal-ceramic crowns[J].J Prosthet Dent, 1985,53(2): 153~157
  • 4[3]Marca.Rosenblum,Allans Chulman A review of All-Ce-ramic J estorations[J]. ADA, 1997, 128(3):297~305
  • 5[6]Amp Miller,jack Ling,Babara Miller,et al. Comparision of the fracture strengths of ceramometal crowns versus several all-ceramic crowns [J].J Prosthet Dent. 1992,68(1):38
  • 6[8]Beschnidt SM,Strub JR. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth[J] .J Oral Rehabil, 1999,26(7):582~593
  • 7[10]Kelly JR,Nishimura I, Campbeu SD.Ceranics in dentistry:Historical roots and current perspectives [J]. J Prosthet Dent 1996,75(1):18
  • 8[14]Jorgenson MW,Goodkind RJ.Sepetrohpotometric study of five porcelain shades relative to the dimensions of color, porcelain thickness,and repeated firings [J].J Prosthet Dent, 1997,42( 1 ): 96
  • 9[18]Hausselt JH. Improvement of porcelain-fused-to-metal compatibility by a new bonding agent[J].J Dent Res, 1982,61:330
  • 10[20]KouhiA,Yoshizo OM,Tomoji M,et al. Properties of test metal ceramic titanium alloys[J]. J Prosthet Dent, 1992, 68: 462