摘要 本研究建立了唾液睾酮(ST)的IEMA(磁性微粒分离的酶联免疫)测定法。结果:平均回收率为92.35%,重复试验平均变异系数<5%,血清睾酮(T)与唾液T相关系数为:男r=0.852,P<0.001,女r=0.902,P<0.001,与其它测定唾液T方法的结果相符。本研究提示唾液T浓度可反映血浆游离T水平,在临床和体育研究中有实际应用价值。 In this study , IEMA method is used to measure salivary testosterone (SI). The results show that the average rate of reclamation is 92.35% the average variation coefficient of the duplicate is < 5%; the relative coefficient of blood T and ST is r=O.852 (P<O.OO1) for male and r=O.902 (P<O.OO1) for female. The results are similar to that from the other methods of measuring ST. The ST measurement in this study can proof the free T?s level of blood. The IEMA technique is better than the other methods and is valuable in the clinical and sports research.
出处 《中国运动医学杂志》 CAS CSCD 北大核心 2001年第4期395-396,共2页 Chinese Journal of Sports Medicine
基金 广西科技发展基金资助项目(No.桂科金9812045)
关键词 唾液睾酮 IEMA法 测定 ST 酶联免疫 salivary testosterone, IEMA measurement
  • 相关文献

参考文献7

  • 1徐仁宝.血浆游离皮质醇的平衡透析法[J].中华医学检验杂志,1980,(3):140-140.
  • 2陆永明.唾液睾酮放射免疫测定[J].男性学杂志,1988,2(1):6-6.
  • 3胡扬,佟启良.唾液睾酮在体育科研中的应用价值及测定[J].北京体育学院学报,1993,16(3):38-42. 被引量:6
  • 4崔毓桂,狄福松,陈家伟,刘标.唾液游离睾酮测定的临床应用[J].实用男科杂志,1996,2(3):149-152. 被引量:1
  • 5崔毓桂,实用男性杂志,1996年,2卷,3期,149页
  • 6陆永仁,男性病学杂志,1988年,2卷,1期,6页
  • 7徐仁宝,中华医学检验杂志,1980年,3期,140页

二级参考文献3