摘要 电流互感器 (TA)饱和会给基于工频电气量的输电线路故障测距精度带来很大的误差。文中利用 MATLAB程序 ,设计了一个前向 BP网络 ,利用 BP网络来对 TA饱和电流进行矫正补偿 ,然后再进行故障测距。EMTP仿真的结果表明 ,对 TA饱和电流进行补偿矫正后 ,明显地改进了故障测距的精度。 Current transformer TA saturation may cause great errors of fault location based on power frequency quantities. A m ethod of using an artificial neural network ANN is presented to correct the distortion of current transformer secondary current caused by the TA saturation in this paper. Moreover,a forward BP network is developed through MATL AB program. So,the ANN can be trained to achieve an inverse transfer function of iron- core toroidal current transform ers widely used in protection system.And consequently the com pensated currents are suitable for fault location.The simulation results of EMTP show that the compensation of saturated current by ANN can significantly improve the accuracy of fault location.
机构地区 清华大学电机系
出处 《电力系统自动化》 EI CSCD 北大核心 2002年第1期39-41,52,共4页 Automation of Electric Power Systems
关键词 电流互感器 饱和 神经网络 继电保护 测距精度 电力系统 输电线路 fault location current transformer saturation artificial neural network protective relaying
  • 相关文献

参考文献12

  • 1葛耀中(Ge YaoZhong). 新型继电保护与故障测距原理与技术(New Types of Protective Relaying and Fault Location Theory and Techniques). 西安:西安交通大学出版社(Xi'an: Xi'an Jiaotong University Press), 1996
  • 2贺家李,宋从矩(He Jiali, Song Congju). 电力系统继电保护原理(The Theory of Electric Power System Protective Relaying). 北京:水利电力出版社(Beijing: Hydraulic and Electric Press), 1994
  • 3葛荣尚,胡家为,黄慎仪.特大电流下电流互感器传变特性探讨[J].电力系统自动化,2000,24(5):32-35. 被引量:26
  • 4何奔腾,马永生.电流互感器饱和对母线保护的影响[J].继电器,1998,26(2):16-20. 被引量:24
  • 5Kang Y C, Park J K, Kang S H, et al. An Algorithm for Compensation Secondary Current of Transformers. IEEE Trans on Power Delivery, 1997, 12(1): 116~124
  • 6Chen K W, Glad S T. Estimation of the Primary Current in a Saturated Transformer. In: Proceeding of the 30th Conference on Decision and Control. Brighton (UK): 1991. 2363~2365
  • 7Cummins J C, Yu D C, Kojovic L A. Simplified Artificial Neural Network Structure with the Current Transformer Saturation Detector Provides a Good Estimation of Primary Currents. IEEE Trans on Power Delivery, 1997, 12(1): 1373~1378
  • 8Yu D C, Cummins J C, Kojovic L A. Neural Network for Current Transformers Saturation Correction. In: Transmission and Distribution Conference. New Orleans (US): 1999. 441~446
  • 9余晓丹,刘众仆,王钢,贺家李.应用模糊神经网络实现故障测距[J].中国电力,1998,31(3):10-13. 被引量:8
  • 10王晓茹,伍思涛,钱清泉.一种基于神经网络的高压输电线故障分类器[J].电力系统自动化,1998,22(11):28-31. 被引量:9

二级参考文献20

  • 1董新洲,葛耀中.一种使用两端电气量的高压输电线路故障测距算法[J].电力系统自动化,1995,19(8):47-53. 被引量:80
  • 2罗姗姗,贺家李,王荣琴.母线保护中电流互感器饱和检测新判据[J].电力系统及其自动化学报,1996,8(3):29-36. 被引量:22
  • 3Chowdhury B H,Proceedings of the Conference on Intelligent System Applications to Power System,1996年,194页
  • 4马松德(译),自适应模式识别与神经网络,1992年
  • 5李永庄(译),电力系统电磁暂态计算理论,1991年
  • 6孙军(译),微处理机式继电器和保护系统,1990年
  • 7Qi W,Proceedings of the Conference on Intelligent System Applications to Power System,1996年,226页
  • 8黄德双,神经网络模式识别系统理论,1996年
  • 9葛耀中,新型继电保护与故障测距原理与技术,1996年
  • 10Xuan Q Y,DPSP & C’94,1994年,404页

共引文献117

同被引文献103

引证文献11

二级引证文献118

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部