根据某涤纶长丝车间的具体情况 ,对其排烟设计作了探索和实践 ,对现行的防火设计规范在化纤行业的适用性提出了个人见解 。
According to the concrete conditions of a PET (polyephylene terephthalate) filament project, presents a personal idea on smoke extraction design, questioning a few points in the current fire prevention code. Suggests that the fire prevention code special for chemical fiber plant should be revised appropriately by the related authoritieszed department.