摘要
通过静态腐蚀阻垢实验、动态旋转挂片腐蚀试验、电化学性能测试试验和现场应用等数据证明 ,使用缓蚀阻垢剂TS - 5 0 30 4能够有效控制氯乙烯转化器列管的腐蚀 ,腐蚀泄漏率由使用前的 3 .5次 /月下降到目前的 1.2次
Results of static corrosion and scale inhibition test,dynamic rotating hanging sample corrosion test,electrochemical propery test and field application show that corrosion and scale inhibitor TS-50304 can control the corrosion of tube of vinyl chloride converter.After using TS-50304,the leaking number caused by corrosion reduces from 3.5 per month to 1.2 per month.
出处
《聚氯乙烯》
CAS
2001年第5期58-60,共3页
Polyvinyl Chloride