期刊文献+

应用滤波器组相关法去噪以检测心室晚电位 被引量:1

Detect Ventricular Late Potentials Using Filter Bank and Correlation Method
下载PDF
导出
摘要 目的在心室晚电位的检测中 ,最大可能地保留晚电位在拍与拍间的变化。方法使用滤波器组 ,根据连续两拍心电信号间的相关特性检出QRS终点。结果仿真心电信号终点检出率在较低噪声时表现相当平稳地在 95%以上 ,只有当噪声增至高于 6μV时才明显的开始滑落 ,直到约 7μV时仍接近 90 %。而在临床心电信号实验中 ,只通过两拍亦取得与临床诊断相符的结果。 Objective To reserve as much as possible of ventricular late potentials(VLP) variance from beat to beat. Method Using filter bank, to detect QRS endpoint according to the correlation of two beats. Result For simulation data, the detecting rate can be stable at >95% for relative low noise level, and become lower until the noise level increases to 6 μV. The detecting rate will still near 90% when the noise is up to 7 μV. For clinical data, using only two beats can achieve the result match with clinical diagnostic. Conclusion Using this method can detect beat to beat variance of VLP.
出处 《航天医学与医学工程》 CAS CSCD 北大核心 2001年第3期201-205,共5页 Space Medicine & Medical Engineering
关键词 滤波器组 相关系数 电位 QRS波群 小波 心室晚电位 filter bank correlation coefficients potentials cardiac ventricles QRS complex wavelet
  • 相关文献

参考文献6

  • 1韦孟宇 周礼杲.心拍滤波器及小波变换在检测心室晚电位变化的应用.99中国生物医学电子学学术年会论文集[M].,1999.126-127.
  • 2Vai M I,Proc IEEE EMBS Asia Pacific Conference on Biomedical Engineering Part 1/2,2000年,129页
  • 3韦孟宇,99’中国生物医学电子学学术年会论文集,1999年,126页
  • 4杨褔生,小波变换的工程分析与应用,1999年
  • 5Vai M I,Proc 20th Annual Int Conf IEEE EMB Spart 1/6,1998年,20卷,227页
  • 6张开滋,心电信息学,1998年,427页