摘要
介绍了一种新型全自动光电式药粒、片剂装瓶数粒机的系统结构和工作原理 .并着重分析了该种数粒机可编程控制器计数系统中气动快门响应速度、可编程控制器扫描速度等因素对计数准确率的影响 。
Presents the working process and the systematic structure of counting machine with photoelectronics for the drug package, which is the key equipment in the newly automatic for tablet drug, especially discusses the influences of response speed of the pneumatic shutter in the counter with PLC, the scanning velocity of the PLC, on the accuracy of the counting, and points the improvement methods of controlling system of for the photoelectronic counter as well.
出处
《佳木斯大学学报(自然科学版)》
CAS
2001年第4期340-342,共3页
Journal of Jiamusi University:Natural Science Edition