摘要
在大同第二发电厂的零排放项目中 ,采用Aquapure连续微滤技术代替常规的澄清作为反渗透的预处理 ,并通过工业性试验验证了工艺的可行性。作者就连续微滤技术本身以及它在反渗透预处理的应用情况作了详细介绍 。
In Zero Discharge Project of Datong No2 Power Station,auther use Aquapure continuous microfiltration technology instead of conventional clarification and filtration as RO pre treatment,and pass the industrial test to prove the feasibility of this process. Continuous microfiltration technology and its application in RO pre treatment are fully detailed. Continuous microfiltration technology and conventional clarification and filtration technology are compared in technology and economy aspects.
出处
《工业水处理》
CAS
CSCD
2001年第12期31-33,共3页
Industrial Water Treatment