摘要 目的 研究不同种类的熔模材料对玻璃陶瓷全冠精度的影响 ,以及适合性方面为玻璃陶瓷全冠临床用蜡提供实验依据。方法 采用不同蜡制做三组全冠熔模 ,共 18个 ,每组 6个。制作玻璃陶瓷全冠 ,测试并比较全冠各部位、各组全冠的适合性。结果 三组全冠的适合性无显著性差异 (P >0 .0 5 )。第二组冠的适合性略优于其它两组 ,第三组即普通技工用蜡所铸冠的适合性较差 ,但也在临床接受范围内 ( <12 0 μm )。结论 底层为舒张蜡 。 Objective To evaluate the influence of different wax pattern materals on the adaptation of Dicor all ceramic crown.Methods There were three groups full ceramic crown’s wax patterns.They were fabricated with three kinds of different materals.Dicor full ceramic crown was constructed using a standardized technique.At last,the adaptation of the three groups full ceramic crowns was measured and compared.Results They hardly showed significant difference( P > 0.05 ).However,the second group was considered as the first rate for its adaptation.Although the third group crown’s resin was thicknest,it was conformed to standards of clinic(<120 μm).Conclusion Three kinds of materls are all competent to fabricate wax pattern of Dicor casting glass full ceramic crown,but the second group’s materal is the perfectest among the three kinds of materals.
出处 《临床口腔医学杂志》 2001年第4期276-277,共2页 Journal of Clinical Stomatology
关键词 熔模 铸造玻璃陶瓷 全冠 适合性 精度 牙科材料 wax pattern casting glass ceramic full crown adaptation
  • 相关文献

同被引文献34

  • 1高法章,赵云凤.铸模焙烧温度对Plat铸造陶瓷全冠适合性的影响[J].口腔材料器械杂志,1994,3(1):14-15. 被引量:1
  • 2杨晓喻,刘长虹,巢永烈,李宁.牙用烤瓷支架钴铬钼合金热膨胀系数的测定[J].广东牙病防治,2006,14(2):114-115. 被引量:10
  • 3Randa Diwan, Yousef Talic, Noura Omar, et al. Pattern waxes and inaccuracies in fixed and removable partial denture castings. J Prosthet Dent, 1997,77(5) = 553 -555.
  • 4Thompson VP, Williams EF, Bailey WJ. Dental Resins with Reduced Shrinkage During Hardening. J Dent Res, 1979,58(5) : 1522 - 1532.
  • 5Takahashi J, Kitahara K, Wangxue, et al. Resin pattern material with low polymerization shrinkage. Int J Prosthodont, 1999 ,t2(4) : 325 - 329.
  • 6Nourallah H, Hammad I. Marginal castability of two different materials (a comparative study). Egypt Dent J, 1994, 40( 1 ) : 649 - 652.
  • 7May KB, Russell MM, Razzoog ME, et al. Precision of fit: the Proeera Alleerarn crown. J Prosthet Dent, 1998, 80(4) : 394 -404.
  • 8Stevens L. Model investing method of FPD construction: its accuracy. Dent Mater, 1986, 2(4) : 166.
  • 9谢贺明.口腔材料学[M].西安:陕西科学技术出版社,1998.85-88.
  • 10Tian AHL, Li T, Logan GI et al. Marginal accuracy of complete crowns made from alternative casting alloys [J]. J ProsthetDent, 1991, 66 (2) :152~164