摘要
冻土层等效导热系数λ 是保温防冻设计中保温层厚度计算的重要参数。依据河北省王村冻土试验场的观测成果分析 ,λ 的主要影响因素为水分条件 ,并提出了重粉质壤土λ 与地下水埋深的关系式以及λ
equivalent coefficient of heat conductivity, is an essential parameter to calculate thickness of thermo insulating layer in the design. On the basis of observation results of Wangcun frozen-soil testing field in Hebei, this paper puts forward that the major influence factor of λ * is moisture condition, and also puts forward on the condition of heavy silty soil the relation of λ * and groundwater depth and the retation of λ and groundwater depth and moisture conteut before freezing.
出处
《防渗技术》
2001年第2期20-21,24,共3页
Technique of Seepage Control
关键词
冻土
等效导热系数
保温
水分条件
防冻
equivalent
coefficient of heat conductivity
thermo insulating