期刊文献+

红外光谱法测定(乙醇)醚化催化汽油中残余乙醇的含量 被引量:2

Determination of Residual Ethanol in Etherified FCC Gasoline
下载PDF
导出
摘要 建立了红外光谱法测定 (乙醇 )醚化汽油中残余乙醇的方法 ,运用可调厚度吸收池消除汽油背景所产生的影响。当乙醇质量浓度为 1 5~ 13g/dl时 ,其误差为 0 1%~ 1 5 % ,相对标准偏差小于 3 % ,回收率为 99 2 %~10 1 5 %。该方法简单、快速、准确 。 An infrared spectrophotometric method for determining residual ethanol in etherified FCC gasoline is established.The effect caused by gasoline background is removed by a variable space cell.For ethanol contents within the range of 1 5~13 g/dl,the error is 0 2%~1 6%,RSD is 2%,and recovery is 98 5%~101%.The method is simple,rapid,accurate and also can be applied to the determination of ethanol in unleaded gasoline.
出处 《石油化工》 CAS CSCD 北大核心 2002年第2期132-134,共3页 Petrochemical Technology
关键词 红外光谱法 催化汽油 乙醇 测定 醚化 infrared spectrometry FCC gasoline ethanol
  • 相关文献

参考文献3

  • 1Aleksandrov A N,Tysovskll G I.Neftepereab[C].Moscow:Neftekhim,1966.37~39.
  • 2Franke G.[J].Erdoel Kohle,1961,14(10):816~820.
  • 3Battiste D R,Fry S E, White F T,et al.[J].Anal Chem,1981,53:1096~1099.