摘要
分析了太原第一热电厂 DG— 1 0 2 5型锅炉中间储仓式制粉系统的钢球装载量、粗粉分离器挡板开度、磨煤机出力、磨煤机通风量等参数对煤粉细度和磨煤机电耗的影响 。
According to the result of coal pulverizing system experiment, Analysis have been made for parameters of the change of steel ball, damper opening of classifier separater, mill capacity and ventilation of mill on coal fineness and mill power consumption.reasonable suggestion of optimization has been put forward.
出处
《山西电力》
2001年第6期5-6,12,共3页
Shanxi Electric Power