摘要 用微孔滤膜采集空气中铅 ,然后溶解于稀硝酸中 ,将含有铅离子的溶液用微分电位溶出法测定 ,该方法的最低检测浓度为 0 .2 5 μg/L ,测定范围 0~ 30 0 μg/L ,相关系数r=0 .9992 ,相对标准偏差为 0 .6~ 2 .3% ,回收率为 95 .6~ 10 4.2 % ,平均采样效率为 97.2 %。本方法可较好地应用于作业场所空气中铅的测定。 The papper reported collection of lead in air by mivr omesh Filter film and then dissolving in rare nitric acid. The sample s olutio n for lead were determined by Differential Potential Stripping Analysis. The Low est detected density is 0.25μg/L, the linearity is very good between 0~300μg/ LRelative standard deviation is 0.6~2.3% and the recovery ration 95.6 ~104.2% while, average collect efficiency is 97.25.This method can be used to d etect lead in workplace air effectively.
出处 《中国卫生检验杂志》 CAS 2001年第5期517-519,共3页 Chinese Journal of Health Laboratory Technology
关键词 微分电位溶出分析 微孔滤膜 作业场所 Lead Differential Potential Analysis Micromesh filter film