期刊文献+

混凝土结构植筋锚固刍议 被引量:22

On Anchorage of Steel Bars in R.C.Structure
下载PDF
导出
摘要 混凝土结构植筋锚固的使用受多种因素制约 ,植筋锚固材料的耐久性、稳定性、耐火性、使用部位、钢筋锚固长度、锚固区混凝土的约束等在设计时都应慎重考虑。文中还对专用水泥的部颁标准《无收缩快硬硅酸盐水泥》(ZBQ1 1 0 0 9— 88)配制的浆锚砂浆用于钢筋锚固。 Glued joints for steel bars applied in concrete structure are limited by many factors, including fire resistance and stability, position in the structure, anchorage length of steel bars, confinement of concrete, which should be considered when designing. In addition, this paper introduces the mortar of glued joints mixed with Non shrinkage quick hardening Portland cement (ZBQ11009 88) and the experimental research of its application in anchorage of steel bars and lapped splices.
作者 孙金墀
出处 《建筑结构》 CSCD 北大核心 2002年第1期26-30,共5页 Building Structure
关键词 混凝土结构 植筋 耐火性 锚固长度 浆锚砂浆 glued joints fire resistance anchorage length steel bar concrete limit anchor area mortar