摘要
文章介绍了南京院自行开发的NCDJ80m2电除尘器在河南中州铝厂4.5m×100m三氧化二铝窑尾的应用。该电除尘器应用1年多来,经环保部门多次测定,其排放浓度(标况)<100mg?m3,达到了设计目标值及当地环保指标。
This article introduces the application of the NCDJ80m 2 electro-static precipitator in Zhongzhou Aluminum Plant,Henan Province for dedusting at the feed end of the Al 2 O 3 kiln of *I4.5m×100m in size.During its operation of over one year,the tests made by the environmental protection authorities show that the emission(Normal State)is<100mg*/m 3 ,meeting the design target and the local environment index.
出处
《水泥工程》
CAS
2002年第1期56-59,共4页
Cement Engineering