通过试验分析找出了电雷管网路在泥水中成片拒爆的原因是电雷管脚线和壳体间绝缘强度不足 。
The cause of tracts misfire of electric firing network in slurry is analyzed by experiment.The lower insulation intensity between cap leads and cap shell is the main cause.The countermeasures are put forward in accordance with misfiring.