期刊文献+

温室缀铝膜保温幕节能性能的实验研究初报 被引量:14

Preliminary Experimental Research on Effect of Aluminized Thermal Screens in Greenhouse
下载PDF
导出
摘要 用国产缀铝保温膜幕在温室内进行了保温节能实验。测定比较了有、无保温幕二种情况下的室内气温 ,结果表明 ,在该实验条件下 ,采用缀铝膜保温幕时温室内外温差提高了 3~ 5℃ ,保温幕上、下 4 0 cm处温差平均达到8.8℃。测定了温室有、无保温幕时的供暖量 ,并计算了屋面传热系数 ,得出缀铝膜保温幕的节能率达到 37% 。 Heat preservation and energy saving experiment using aluminized thermal screens in greenhouse was conducted. The temperatures inside greenhouse both with and without thermal screens were measured based on experiment. The experimental result showed that air temperature inside greenhouse under aluminized thermal screens can be improved by 3~5℃, and the air temperature at 40 cm above the screen was 8.8℃ higher than that at 40 cm under the screen. According to calulated results of the heating load of the greenhouse and the overall heat transfer coefficient of the roof with and without thermal screens, the average energy saving efficiency reached about 37%, which reveals excellent thermal performance of aluminized thermal sreens.
出处 《农业工程学报》 EI CAS CSCD 北大核心 2002年第1期89-92,共4页 Transactions of the Chinese Society of Agricultural Engineering
基金 高等学校骨干教师资助计划资助
关键词 温室 缀铝膜 保温幕 节能性能 实验研究 greenhouse aluminized film thermal screen energy saving
  • 相关文献

参考文献2

二级参考文献4

共引文献18

同被引文献179

引证文献14

二级引证文献94

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部