期刊文献+

基于通用串行总线的主机与小型医学仪器互连的研究 被引量:3

Interconnecting Small Medical Apparatuses to a Computer Based on Universal Serial Bus
下载PDF
导出
摘要 目的探讨实现主机与小型医学仪器互连的方法 ,以便最终实现小型医学仪器的网络化。方法本文提出了利用通用串行总线 (USB)实现主机与小型医学仪器互连的方案 ,同时解决了此方案中最关键的技术 ,即如何利用USB总线实现医学信号的实时数据采集和传输 ,具体工作包括硬件设计、固件设计、驱动程序设计和应用程序设计。结果利用USB总线实现了医学信号的实时数据采集和传输 ,为下一步实现医学仪器与主机互连打下了基础。 Objective To investigate the method for interconnecting small apparatuses to a computer, so that a network of small apparatuses can be constructed. Method This paper presents a USB based method to interconnect small apparatuses to a computer, and to achieve the real time data acquisition and data transfer of medical signals. Result Data acquisition and data transfer of medical signals were implemented by using USB. It provides basis for interconnecting small medical apparatuses to computer. Conclusion The USB based method of interconnecting small medical apparatuses to computer is practical.
出处 《航天医学与医学工程》 CAS CSCD 北大核心 2002年第1期68-71,共4页 Space Medicine & Medical Engineering
基金 国家自然科学基金资助 ( 5 993716 0 )
关键词 通用串行总线 医学仪器 数据采集 网络 计算机 universal serial bus medical apparatuses data acquisition net work computer
  • 相关文献

参考文献3

二级参考文献6

  • 1李翠微,郑崇勋.ECG自动分析技术的发展[J].国外医学(生物医学工程分册),1994,17(1):15-22. 被引量:23
  • 2王博亮,刘希顺,黄晓玲.心电信号中QRS波群的实时检测算法[J].航天医学与医学工程,1995,8(1):23-26. 被引量:6
  • 3杨福生,小波变换的工程分析与应用,1999年
  • 4Ye Jian,Signal Acquisition,Modeling and Analysisof the Pulmonary Circulation System [M],1993年
  • 5Chung Y C,Respiratory Interference Elim inationfrom Im pedance L ung Rheogram [M],1988年
  • 6顾慎为,阻抗血流图,1986年

共引文献22

同被引文献21

  • 1LI Xiangning ZHOU Wei LIU Man ZENG Shaoqun LUO Qingming.Firing patterns of long-term cultured neuronal network on multi-electrode array[J].Progress in Natural Science:Materials International,2006,16(12):1337-1342. 被引量:7
  • 2陈传平,陈琳,林云生,曾绍群.培养神经元网络对不同间隔电脉冲刺激的响应[J].航天医学与医学工程,2006,19(6):442-446. 被引量:4
  • 3李艳玲,李向宁,周炜,曾绍群,刘曼,骆清铭.培养海马神经元网络学习模型的构建[J].生物化学与生物物理进展,2007,34(2):169-175. 被引量:3
  • 4LI Xiangning,ZHOU Wei, ZENG Shaoqun, et al. Long-term recording on multi-electrode array reveals degraded inhibitory connection in neuronal network development [ J ]. Biosensors and Bioelectronics, 2007, 22 (7) : 1538-1543.
  • 5LI Yanling,ZHOU Wei, LI Xiangning, et al. Characterization of synchronized bursts in cultured hippocampal neuronal networks with learning training on microelectrode arrays [ J ]. Biosensors and Bioelectronics, 2007, 22(12) : 2976-2982.
  • 6LI Yanling,ZHOU Wei, LI Xiangning, et al. Dynamics of learning in cultured neuronal networks with antagonists of glutamate receptors[J]. Biophysical Journal, 2007, 93 (12) : 4151-4158.
  • 7Potter SM, Wagenaar DA, DeMarse TB. Closing the loop: stimulation feedback systems for embodied MEA cultures [ M]. in: Taketani M, Baudry M, eds. Advances in Network Electrophysiology Using Multielectrode Arrays. New York: Springer, 2006: 215-242.
  • 8Corbet J,Rubini A, Kroah-Hartman G. Linux Device Drivers [ M]. 3rd Edition. Beijing: O' Reilly Media, Inc. and China Electric Power Press, 2006 : 9-14.
  • 9Wagenaar DA, DeMarse TB, Potter SM. MeaBench : A toolset for muhi-electrode data acquisition and on-line analysis [ C ]. In: Akey M, Proceedings of the 2nd International IEEE EMBS Conference on Neural Engineering. Washington D. C. : IEEE Press, 2005 : 518-521.
  • 10Love R. Linux Kernel Development [ M ]. 2nd Edition. Beijing: Pearson Education Asia Limited and China Machine Press, 2006 : 44-46.

引证文献3