变压器油中局部放电信号超高频特性的研究 被引量:25

Study on ultra-high-frequency characteristics of partial discharge signals in transformer oil
下载PDF
导出
摘要 理论分析表明 ,局部放电信号所激发的电磁波具有很宽的频谱 ,它以TEM波的形式向外传播。本文通过实验模拟的方法研究了变压器油中的局部放电脉冲电流波形及其所辐射的电磁波特性 ,实验结果表明 ,变压器油中的局部放电电流脉冲具有极快的上升沿 ,能激励起 1 5GHz以上的超高频电磁波 ,它可以通过超高频传感器加以耦合接收 ,这就为进一步研究超高频检测技术在电力变压器中的应用提供了依据。 Theoretical analysis shows that E\|M waves radiated by discharges in transformer oil have wide band spectrum, and are propagated as transverse E\|M waves. In this paper, an experimental study on PD current pulse and the radiated E\|M waves in oil is done, also these relationships are given. Results show that, PD current pulse in oil has a very short risetime, which is capable of generating ultra\|high\|frequency (UHF) signals at frequencies up to at least 1\^5 GHz, and these E\|M waves can be picked up by UHF sensors. Thus the feasibility of applying UHF partial discharge monitoring techniques to an in\|service oil\|filled power transformer is established.
出处 《电工电能新技术》 CSCD 2002年第1期49-53,共5页 Advanced Technology of Electrical Engineering and Energy
关键词 超高频法 局部放电检测 变压器油 传感器 电力设备 绝缘监测 ultra\|high\|frequency method partial discharge detection transformer oil sensor
  • 相关文献

参考文献4

二级参考文献8

  • 1库钦斯基ГC.高压电器设备局部放电[M].北京:水利电力出版社,1984..
  • 2库钦斯基 ГС,高压电器设备局部放电,1984年
  • 3Rutgers W R,10th ISH,1997年,25页
  • 4邱昌容,电工设备局部放电及其测试技术,1994年
  • 5Rutgers W R,The 10th ISH,1997年
  • 6王元坤,线天线的宽频带技术,1995年
  • 7邱昌容,电工设备局部放电及其测试技术,1994年
  • 8覃剑,王昌长,邵伟民.特高频在电力设备局部放电在线监测中的应用[J].电网技术,1997,21(6):33-36. 被引量:61