摘要
对引进410t/h CFB锅炉流化床冷渣器进行了试验研究,研究结果表明,冷渣器内的床层压降、流化烟气、冷却水、脉冲阀开关时间等参数对冷渣器的运行状态有较大的影响。在上述研究基础上,提出了相应的改进建议.
Experimental study on the bottom ash coolers in the 410t/h CFB boiler have been carried in this paper. The experiment results indicate that pressure drop, fluidized flue gas, cool- ing water, open and close time of pulse valve have big influence on the operation characteristics of the bottom ash coolers. In terms of above study, the paper then brings forward aPpropriate modification suggestions.
出处
《锅炉技术》
北大核心
2001年第10期17-20,共4页
Boiler Technology