摘要
对氮水预冷水质采用化学处理和离子高压静电水处理两种情况进行比较、分析,证明采用离子高压静电水处理氮水预冷却水,在处理效果和处理成本、费用及管理、操作、防污染上优于化学加药处理。
Precooling water of nitrogen gas-water was treated with chemical method and high voltage ion electrostatic method. The two methods were compared. It showed that the high voltage ion electrostatic method had an advantage over the chemical method in treatment effect and costs, other expenses, management, operation and antipollution.