滑参数停炉、停机的试验研究 被引量:4

Experimental Study of Boiler and Turbine Shutdowns under the Operating Condition of Sliding Parameters
下载PDF
导出
摘要 机组滑参数停炉、停机在开滦热电公司尚属首次。通过本次试验摸索出滑参数停炉、停机的经验 ,可有效地指导今后机组的滑停。作者详尽地概述了滑参数停炉、停机的必要性、滑停应具备的条件和临时监控措施以及滑停中的具体操作 。 The boiler and turbine shutdown of a power plant under the operating condition of sliding parameters was conducted for the first time at Kailuan Thermal Power Co. By carrying out this trial the Co. has accumulated the experience of boiler and turbine shutdown under the sliding parameters condition, which can serve as an effective guide for a plant shutdown under such circumstances. A detailed account is given concerning the necessity for and requisite conditions of such shutdowns as well as the temporary monitoring measures and specific operation procedures required in this regard. An analysis was given of the influence of such shutdowns on a power plant. Some issues demanding special attention are also presented.
作者 赵斌
机构地区 开滦热电公司
出处 《热能动力工程》 EI CAS CSCD 北大核心 2001年第5期554-557,共4页 Journal of Engineering for Thermal Energy and Power
关键词 锅炉 汽轮机 滑停 试验 停炉 停机 boiler, steam turbine, plant shutdown under sliding parameters, test