摘要
祖国医学用中指中节同身寸度量取穴,具有一定的价值。本文用改良的中指中节同身寸度量食道心房调搏的导管电极,其直线回归方程(?)=28.27+2.22x,但实际应用不便;再经统计学处理,电极到达左房中部约相当于本人9.45—10.87同身寸,在应用组20例中获得成功。此法简单易行,准确性高。
Using digitus medius-middle phalanx identical unit to select points is of certain value in traditional Chinese medicine.A modified method of digitus medius identical unit is used for measuring the electrode in esophageal atrial pacing.A linear regression equation =28.27+2.22x has been worked out,but it is inconvenient for applicatin.Having been treated statistically,when the pacing electrode reaches the middle part of the left atrium,it is about 9.45-10.87 digitus medius identical units of the person himself.This method has been practised upon twenty cases and proved successful.It is not only simple and easy to practise but also with high accuracy.
出处
《江西医学院学报》
1989年第1期61-63,共3页
Acta Academiae Medicinae Jiangxi