期刊文献+

聚醚砜中空纤维膜对血液中溶质的清除性能 被引量:6

Solute Clean Property of Polyethersulfone (PES) Hollow Fiber Hemofiltration Membranes for the Blood
下载PDF
导出
摘要 将PES膜封装固定在聚碳酸酯壳体内 ,组装成中空纤维膜血液滤过器。用尿素、肌酐、VitB12 和生理盐水配成的模拟液 ,以及此模拟液与血液的混合液作为测试介质 ,进行评价。蛋白质的测定采用双缩脲法 ,尿素、肌酐和VitB12 浓度的测定采用分光光度法。模拟液中尿素、肌酐和VitB12 的筛分系数分别为 96 %、10 0 %、83% ,在TMP为113± 13kPa条件下 ,清除率分别 5 8.6mL/min、6 1.0mL/min、5 0 .6mL/min ,清除分数分别为 0 .2 9、0 .31、0 .2 5。血液中尿素、肌酐和VitB12 的筛分系数分别为 10 0 %、10 0 %、72 % ,清除率分别为 2 9.0mL/min、2 9.0mL/min、2 0 .9mL/min ,清除分数 0 .15、0 .15、0 .10。对蛋白质的筛分系数 1.8% ,可以看出聚醚砜中空纤维膜滤过时的介质不同 ,滤过清除性能也不同。该膜能较好地清除血液中的尿素、肌酐和VitB12 ,从而可望成为一种较好的血液滤过膜。 Seal and fix PES membrane in the Polycarbonate (PC) shell to form a hollow fiber membrane hemofilter. Use urea, creatinine, Vitamin B 12 and normal saline to compose a simulated solution. The simulated solution and its mixture with blood are determined respectively. Determine protein by biuret.Determine the concentration of urea, creatinine and Vitamin B 12 by measuring the optical density with spectrophotometer.The sieving coefficients of urea, creatinine, and Vitamin B 12 of the simulated solution are 96%, 100% and 83% respectively. When transmembrane pressure ( TMP ) are 113±13?kPa, the clearance of urea, creatinine and Vitamin B 12 are 58.6?mL/min, 61.0?mL/min and 50.6?mL/min respectively, and clear fraction of these are 0.29, 0.31 and 0.25. The sieving coefficient of urea, creatinine, and Vitamin B 12 of the blood are 100%, 100% and 72% respectively. At the same TMP , the clearance of urea, creatinine and Vitamin B 12 is 29.0?mL/min, 29.0?mL/min and 20.9?mL/min respectively, and the clear fraction of blood are 0.15, 0.15 and 0.10. The sieving coefficient of protein is 1.8%. PES hollow fiber hemofiltration membrane can effectively clean the urea, creatinine and Vitamin B 12 of the blood, and it is a prospective membrane for hemofilter.
出处 《四川大学学报(工程科学版)》 EI CAS CSCD 2002年第1期69-71,共3页 Journal of Sichuan University (Engineering Science Edition)
基金 国家"九五"项目 (97-5 64 -0 1-0 5 )
关键词 聚醚砜 中空纤维膜 血液滤过 清除率 人工肾 肾功能衰竭 尿毒症 筛分系数 polyethersulfone hollow fiber membrane hemofiltration clearance
  • 相关文献

参考文献5

  • 1[1]Solomon B A. Membrane sepaaration: technogical principles and issues[J]. Trans ASAIO,1981,27:345~49.
  • 2[2]Sueoka A, Takakura K. Hollow fiber membrane application for blood treatment[J] . Polymer, 1991,21(5): 561~571.
  • 3[3]ISO-8637-1989(E), Haemodialysers, hemofilters and hemoconcentrators[S].
  • 4[5]王志刚.血液净化学[M]. 北京:北京科学技术出版社, 1993 .
  • 5[6]Nouhad O. Kronfol. Effect of CAVH membrane types on drug-sieving and clearances [J]. Trans ASAIO,1986, 32:85~87.

同被引文献44

引证文献6

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部