摘要
中性点经消弧线圈接地的谐振接地方式在我国中压电力网中广为采用,但目前仍以 手动调谐居多.针对这一现状,根据模糊控制理论设计了可进行补偿电网脱谐度自动跟踪 调谐的模糊控制器,微机系统通过查找查询表完成调谐任务,所需设备较少,实时性良好.
Neutral resonant grounding is wildly used in intermediate voltage distribution network in our country, and the methods of resonate regulation are mainly artificial adjustment. To counter this fact, a Fuzzy controller for compensation network turn-off-degree automatic resonant is designed in this paper. It has important practically significance in technological innovation from artificiality to automatizition, may rated as a new attempt in the field of Peterson coil's automatic resonance.
出处
《河北工业大学学报》
CAS
2001年第4期88-92,共5页
Journal of Hebei University of Technology