期刊文献+

应用冠脉血流显像技术检测猪心外膜和心肌内冠脉血流特征的实验研究 被引量:2

Assessment of epicardial and intramyocardial coronary flow using a new echocardiographic system in a closed chest swine model
下载PDF
导出
摘要 目的 应用冠脉血流显像技术检测猪的冠脉血流,初步探讨心外膜和心肌内冠脉的时相性灌注特点及其在冠脉扩张状态下的变化。方法 5条实验小型猪,在麻醉状态下应用超声冠脉血流显像技术探测不同节段心外膜冠脉和左室心肌肉的冠脉血流信号,记录其血流频谱曲线。观察心外膜及心肌肉冠脉的时相灌注特点,测定冠脉血流速度,计算右冠脉和前降支的舒张期/收缩期峰值血流速度比值。观察静脉推注潘生丁(0.56mg/kg)后前降支和心肌肉冠脉血流信号及其频谱曲线特点的变化。结果所有动物均可检测到较清晰的心外膜和心肌肉冠脉血流信号;心外膜冠脉为全心动周期前向灌注,右冠脉的收缩期血流速度明显高于前降支;心肌肉冠脉的时相灌注特点为收缩期出现低速的逆向血流;静注潘生丁使心外膜与心肌肉冠脉的血流均明显增强,但灌注模式未变。结论 彩色多普勒冠脉血流显像技术为研究冠脉血流的时相性灌注特点提供了很好的无创性检测手段。 Objectives This study was performed to determine the phasic perfusion character of epicardial and intramyocardial coronary blood flow and the changes of that during dipyridamole administration using coronary flow imaging. Methods In five juvenile swines, coronary flow imaging system were used to visualize the different segments of epicardial coronary arteries and intramyocardial arteries. Pulsed - Doppler spectrums were analysised respectively and the diastolic/systolic velocity ratio of the right coronary artery and the left anterior descending branch was calculated. The left anterior descending and intramyocardial coronary blood flow signals and related pulsed - Doppler spectrums were recorded at baseline and during dipyridamole administration. Results The epicardial and intramyocardial coronary arteries could be visualized by coronary flow imaging. The systolic component of coronary flow in RCA was greater than that in LAD. The intramyocardial blood flow was characterized by persistent retrograde blood flow velocity during systole. Vasodilation with dipyridamole produced exaggerated differences of the phasic pattern of coronary blood flow in epicardial and intramyocardial vessels. Conclusions The color Doppler coronary flow imaging provided a noninvasive method to study the phasic character of coronary blood flow.
出处 《上海医学影像》 2002年第1期59-61,F003,共4页 Shanghai Medical Imaging
关键词 冠脉血流显像 时相性灌注特点 潘生丁 冠脉血流 心外膜 心肌内冠脉 Coronary flow imaging Phasic perfusion character Dipyridamole
  • 相关文献

参考文献4

  • 1[2]Rio CGD, Taylor GW, Nanda NC, et al: Color Doppler visualization of intramyocardial coronary arteries using a new echo system: Effect of contrast enhancement and vasodilation. Echocardiography 1996;13(6) :645 - 650
  • 2李治安,王新房,杨娅,刘俐,吕清,谢明星.冠脉血流显像和冠脉解剖的对照研究[J].中国医学影像技术,1998,14(1):1-3. 被引量:40
  • 3[4]Marcus M, Wright C, Doty D, et al: Measurements of coronary velocity and reactive hyperemia in the coronary circulation of humans.Circ Res 1981;49:877
  • 4[5]Chilian WM, Marcus ML: Phasic blood flow velocity in intramural and epicardial coronary arteries. Circ Res 1982;50:775

共引文献39

同被引文献12

  • 1王红英,邓又斌,毕小军,杨好意,陈斌,黎鹏.经胸冠脉血流显像评价冠脉搭桥术后桥管远端血流动力学状态[J].中国超声医学杂志,2007,23(3):203-205. 被引量:2
  • 2Gaddi O,Tortorella G,Picano E,et al.Diagnostic and prognostic value of vasodilator stress echocardiography in asymptomatic Type 2 diabetic patients with positive exercise thallium scintigraphy:a pilot study.Diabet Med,1999,16(9):762-766.
  • 3Katsuomi Iwakura,Hiroshi Ito,Shigeo Kawano,et al.Assessing myocardial perfusion with the transthoracic Doppler technique in patients with reperfused anterior myocardial infarction:comparison with angiographic,enzymatic and electrocardiographic indices.Eur Heart J,2004,25:1526-1533.
  • 4Brownlee M.Biochemistry and molecular cell biology of diabetic complications.Nature,2001,414:813-820.
  • 5Kersten JR,Brooks LA,Dellsperger KC.Impaired microvascular response to graded coronary occlusion in diabetic and hyperglycemic dogs.Am J Physiol,1995,268:H1667-H1674.
  • 6Kessler L,Wiesel ML,Attali P,et al.Von Willebrand factor in diabetic angiopathy.Diabetes Metab,1998,24:327-336.
  • 7Iwakura K,Ito H,Takiuchis,et al.Alteration in the coronary blood flow velocity pattern in patients with no reflow and reperfused acute myocardial infarction.Circulation 1996,94:1269-1275.
  • 8Yoshitstsu M. Miyamoto Y, Milsuno M, et al. Changes in lefl anterior descending coronary artery flow profiles afler coronary ar tery bypass grafling examined by means of transthoracic Doppler echocardiography. J Thorac Cardiovasc Surg, 2003, 126 (5): 1531 1536.
  • 9Piek JJ, Koolen JJ, Metting Van Rijn AC, et al. Spectral analysis of flow velocity in the contralateral artery during coronary angioplasty: a new method for assessing. J Am Coll Cardiol, 1993, 21 (7) : 1574-1582.
  • 10Lambertz H, Tries HP, Stein T, et al. Noninvasive assessment of coronary flow reserve with transthoracic signal-enhanced Doppler echocardiography. J Am Soc Echocardiogr, 1999,12(3) : 186-195.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部