期刊文献+

PET探测器晶体研发现状 被引量:3

Research and Development Status of PET Detector Crystals
下载PDF
导出
摘要 本文综述了PET系统γ探测器晶体的研发现状。重点介绍了Na I(Tl)、BGO、LSO/LYSO和CZT的γ探测效率、光产额、光谱、光衰减时间常数、能量分辨率等性能,以及它们对临床PET和小动物PET的整机尺寸、位置分辨率、散射分数以及灵敏度等性能的影响。论文比较了部分国产PET系统和国外PET系统的性能,可为我国PET系统γ探测器晶体的研发与应用提供参考和借荐。 This article reviews the research and development status of γ detector crystals in PET system.We investigated the γ-ray detection efficiency,light yield,spectrum,light decay time constant,energy resolution and other properties of NaI(Tl),BGO,LSO/LYSO and CZT detectors. The performance of clinical PET system and pre-clinical PET system were affected by the crystal material including overall size,position resolution,scattering fraction,and sensitivity. We also compared the performance of domestic and foreign PET systems made by BGO and LSO/LYSO detectors. This research would guide the development and application of PET system design.
作者 范亚明 王天泉 李英帼 黄川 尹永智 陈熙萌 FAN Ya-ming;WANG Tian-quan;LI Ying-guo;HUANG Chuan;YIN Yong-zhi;CHEN Xi-meng(School of Nuclear Science and Technology,Lanzhou University,Lanzhou 730000,China)
出处 《核电子学与探测技术》 CAS 北大核心 2018年第4期533-539,共7页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金(11305083) 兰州大学中央高校基本科研业务费专项(lzujbky-2016-27)资助
关键词 正电子发射断层显像(PET) NaI(Tl)闪烁晶体 BGO闪烁晶体 LSO/LYSO闪烁晶体 CZT半导体 positron emission tomography NaI(Tl) scintillation crystal BGO scintillation crystal LSO/LYSO scintillation crystal CZT Semiconductor
  • 相关文献

参考文献5

二级参考文献23

  • 1甄力莳,李洪斌,杨光,苗颖.PET对经脉循行线研究初试[J].核电子学与探测技术,1997,17(3):234-236. 被引量:1
  • 2[1].TanTXL, Pomeranz SJ. A new frontier in diagnosis and patient care. Applied Radiology, 1995,24: 6-24
  • 3[2]Conti PS, Lifen DL, Hawley K, et al. PET and F18-FDG in Oncology: A cinical updata. Nucl Med Biol, 1996,23: 717-735
  • 4[3]Knox WE, Jamdar SC, Davis PA. Hexokinase, differentiation and growth rates of transplant fumors. Cancer Res, 1970,30:2240-2244
  • 5[4]Som P, Atkins HL, Bandoypadhayay D, et al. A fluorinated glucose analog, 2-fluoro-2-deoxy-2-/d-glucose [ 18 F ]: nontoxic tracer for rapid tumor detection. J Nucl Med, 1980,21:670-675
  • 6[5]Colemen RE. Multicenter perspective study of FDG PET in the evaluation of indeterminate solitary pulmonary nodules. J Nucl Med, 1995,36:94
  • 7[6]Dewan NA, Shehan C J, Reeb SD, et al. Likelihood of malignancy in a solitary pulmonary nodules. Comparison of Bayesian analysis and results of FDG-PET scan. Chest. 1997; 112:416-422
  • 8[7]Patz EF, Lowe VJ, Hoffman JM, et al. Focal pulmonary abnormalities:evaluation with F-18-fluorodeoxyglucose PET scanning. Radidogy, 1993,188: 487-490
  • 9[8]Maron EM, McAdams HP, Erasmus JJ, et al. Staging non-small cell lung cancer with whole-body PET. Radiology, 1999,212: 803-809
  • 10[9]Schiepens C, Penninclx F, De Vadder N, et al. Contribution of PET in the diagnosis in the recurrent colorectal cancer: comparsion with conventional imaging. Eur J Surg Oncol, 1995,21:517-522