期刊文献+

MSCT三维重技术在阑尾炎中临床诊断价值 被引量:1

MSCT Three-Dimensional Technology Clinical Diagnosis Value In Mei Yan Lan
下载PDF
导出
摘要 目的:探究m SCT三维重建技术在诊断阑尾炎中的临床价值,为临床提供指导。方法:以2016年10月11日至2017年10月20日我院84例疑似阑尾炎患者作为观察对象,对84例疑似阑尾炎患者均实施B超检查、m SCT三维重建技术检查,并将检查结果和手术病理检查结果进行对比,研究对比m SCT三维重建技术的诊断价值。结果:m SCT三维重建技术诊断阑尾炎的敏感度、特异度、总准确率分别为95. 83%、100. 00%、96. 43%,B超诊断阑尾炎的敏感度、特异度、总准确率分别为80. 56%、83. 33%、80. 95%,统计发现,m SCT三维重建技术诊断阑尾炎的敏感度、总准确率相比B超明显更高,P <0. 05,但组间特异度无显著差异,P> 0. 05。结论:m SCT三维重建技术诊断阑尾炎具有较好的效果,诊断准确率较高,且敏感度、特异度均较高。 Objective to explore the clinical value of mSCT 3D reconstruction in the diagnosis of appendicitis,and to provide guidance for clinical practice. Methods from October 11,2016 to October 20,2017 in our hospital 84 cases of suspected appendicitis patients as the observation object,the implementation of all B-ultrasound,mSCT three-dimensional reconstruction technique was performed on 84 cases of patients with suspected appendicitis,and comparing the findings and pathological examination results,the diagnostic value of mSCT three-dimensional reconstruction technology comparison. The results of mSCT three-dimensional reconstruction in the diagnosis of appendicitis,sensitivity,specificity and accuracy were 95. 83%,100%,96. 43%,B ultrasound diagnosis of appendicitis in the sensitivity,specificity and accuracy were 80. 56%,83. 33%,80. 95%,statistics show that the 3D reconstruction technology of mSCT fault diagnosis of appendicitis sensitivity and accuracy compared to ultrasound was significantly higher,P < 0. 05,but there was no significant difference between group specificity,P > 0. 05. Conclusion the mSCT 3D reconstruction technique has a good effect in the diagnosis of appendicitis,and the accuracy of diagnosis is high,and the sensitivity and specificity are high.
作者 陈志武 赵仕董 丘武应 朱志铿 刘国文 Chen Zhiwu;Zhao Shidong;Qiu Wu;Zhu Zhikeng;Liu Guowen(Department of radiology of the people's Hospital of Fogang County,Guangdong 511600)
出处 《现代医用影像学》 2018年第6期1852-1854,共3页 Modern Medical Imageology
关键词 MSCT三维重建技术 诊断 阑尾炎 B超 MSCT 3D Reconstruction Technique Diagnosis Appendicitis B Ultrasound
  • 相关文献

参考文献6

二级参考文献62

  • 1张国良,陈九如.CT在急性阑尾炎诊断中的应用[J].国外医学(临床放射学分册),2004,27(4):227-230. 被引量:33
  • 2王康,赵泽华,王之,张国桢,徐嵩森,王伟忠,张淼,奉典旭,刘文瑾.多层螺旋CT非增强三维重建诊断急性阑尾炎的价值探讨[J].临床放射学杂志,2004,23(10):883-886. 被引量:12
  • 3李平,韦伟斌,肖敏.87例异位阑尾炎的诊治体会[J].医学文选,2005,24(2):213-214. 被引量:6
  • 4周宏建,王琳,朱彦凯,王世超,丁兆武.右半结肠癌误诊为急性阑尾炎18例分析[J].腹部外科,2007,20(2):111-112. 被引量:26
  • 5Purysko AS, Remer EM, Filho HM, et al. Beyond appendicitis: common and uncommon gastrointestinal causes of right lower quadrant abdominal pain at multidetector CT. Radiographics, 2011,31:927-947.
  • 6Rao PM, Rhea JT, Novelline RA. Sensitivity and specificity of the individual CT signs of appendicitis: experience with 200 helical appendiceal CT examinations. J Comput Assist Tomogr, 1997, 21 : 686-692.
  • 7Yildirim E,Karagtille E, Kirba I, et al. Alvarado scores and pain onset in relation to multislice CT findings in acute appendicitis. Diagn Interv Radiol, 2008,14:14-18.
  • 8Collins GB, Tan TJ, Gifford J, et al. The accuracy of pre-appen- dectomy computed tomography with histopathological correla- tion., a clinical audit, case discussion and evaluation of the litera- ture. Emerg Radiol, 2014, 21: 589-595.
  • 9Kim HC, Yang DM,Jin W, et al. Added diagnostic value of multi- planar reformation of multidetector CT data in patients with sus- pected appendicitis. Radiographics, 2008, 28: 393-406.
  • 10Humart L, EI khoury M, Lesavre A, et al. What is the thickness of the normal appendix on MDCT? [J]. J Radiol, 2007, 188(3 Pt 1): 385-389.

共引文献181

同被引文献13

引证文献1

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部