摘要
根据竖壁膜式冷凝的边界层传热传质原理得出了无量纲因子Ln对冷凝过程表面传热系数的影响,进行了湿烟气在多排管束换热器中的冷凝传热试验,并由试验数据拟合得到烟气冷凝过程Nu的准则方程。在此基础上研制了大型电站锅炉烟气冷凝换热器并成功运用于某电厂1 000MW机组。结果表明:烟气冷凝换热器实际运行性能参数与设计值吻合,该拟合式可用于工程设计。
By analyzing the effects of dimensionless factor Lnon the surface heat transfer coefficient during condensation process based on the principle of heat and mass transfer in the boundary layer of vertical wall film condensation,a number of condensation heat-transfer tests were conducted on the process of wet flue gas passing through the heat exchangers with multi-row tube bundles,and subsequently an Nuformula was fitted for the heat-transfer process using above experimental data.On this basis,a flue gas condensing heat exchanger was developed for large power plant boilers,which was successfully applied to a 1 000MW power unit.Results show that the actual performance parameters of the flue gas condenser developed agree well with its design values,and the formula fitted may be used in engineering designs of similar flue gas condensers.
作者
刘江宁
雷承勇
LIU Jiangning;LEI Chengyong(SPIC Hebei Electric Power Co.,Ltd.,Shijiazhuang 050000,China;Shanghai Power Equipment Research Institute Co.,Ltd.,Shanghai 200240,China)
出处
《动力工程学报》
CAS
CSCD
北大核心
2018年第12期1004-1007,共4页
Journal of Chinese Society of Power Engineering
关键词
湿烟气
超低排放
烟气冷凝
传热计算
wet flue gas
ultra-low emission
flue gas condensation
heat-transfer calculation