摘要
本文利用气相色谱法,由液体自动进样器直接进样检测,测定水和废水中的乙酸甲酯,方法检出限为0.1 mg/L,方法精密度实验相对标准偏差小于6.36%,同时具有较高的回收率。
In this paper,gas chromatography is used to directly detect the methyl acetate in water and wastewater by liquid autosampler.The detection limit of the method was 0.1mg/L,the relative standard deviation of the precision experiment was less than 6.36%,and the recovery rate was high.
作者
陈浩
Chen Hao(Zhangzhou Gulai Environmental Monitoring Station,Gulei,Fujian 363215,China)
出处
《福建分析测试》
CAS
2018年第6期44-48,共5页
Fujian Analysis & Testing
关键词
乙酸甲酯
气相色谱法
Methyl acetate
gas chromatography