期刊文献+

固相微萃取在苯丙胺类毒品分析中的应用 被引量:5

Application of solid phase microextraction in the analysis of amphetamine-type drugs in the biological samples
原文传递
导出
摘要 固相微萃取(solid phase microextraction, SPME)作为一种新型样品前处理技术已受到广泛关注。由于SPME集采样、萃取、浓缩、进样于一体,克服了传统样品前处理技术步骤繁琐、耗时耗力、所需样品量大等诸多缺点,因此在对生物样品中毒品等目标物的分析中具有巨大的应用潜力。本文以纤维SPME技术为例,综述了该技术在苯丙胺类毒品分析中的研究进展,并对其发展方向进行了展望。 As a new sample pretreatment technique,solid-phase microextraction (SPME)has attracted a lot of attention.SPME integrates sampling,extraction,concentration and injection into a single step and overcomes some drawbacks those conventional pretreatment techniques possess,such as being tedious,time-consuming and requiring large amounts of samples,etc.Therefore,SPME has great application potential in the drug analysis in the biological samples.Based on fiber-SPME,the application of SPME in the analysis of amphetamines in the biological samples is summarized and the further development directions are suggested.
作者 宋爱英 康明星 杨晶 石恩林 王炜 Song Aiying;Yang Jing;Shi Enlin;Wang Wei(School of Public Security &Technology,Gansu Institute of Political Science and Law,Lanzhou 730070,China)
出处 《中国法医学杂志》 CSCD 2018年第6期604-607,共4页 Chinese Journal of Forensic Medicine
基金 国家自然科学基金(21565005) 甘肃省自然科学基金(1506RJZA033) 甘肃省高等学校科学研究项目(2018A-069) 兰州市科技计划项目(2016-3-36) 甘肃政法学院校级重点项目(2017XZDLW02)
关键词 纤维固相微萃取 苯丙胺类毒品 生物检材 法医毒物分析 fiber-solid phase microextraction amphetamine-type drugs biological samples forensic toxicology
  • 相关文献

参考文献2

二级参考文献15

  • 1[1]UNODC.Amphetamine-type stimulants (ATS) pose an increasing global challenge[R].United Nations publica-tion,2003,11.
  • 2[2]UNODC.2007 world drug report[R].United Nations publication,2007,7.
  • 3[4]Hara K,Kashimura S,Hieda Y,et al.Simple extracted derivatization of methamphetamine and its metabolites in biological materials with Extrelut columns for their GC -MS determination[J].J Anal Toxicol,1997,21:54 -58.
  • 4[5]Hara K,Zhao L Internal standards designed for rapid a-nalysis of amphetamine-enantiomers by GC-MS[C].The International Association of Forensic Toxicologists,2003,10.
  • 5[7]Zhao Liu,Kenji Hara,Seiichi Kashimura,et al.Two simple methods for enantiomeric analyses of urinary am-phetamines by GC/MS using deuterium-labeled 1-am-phetamines as internal standards[J].Forensic Toxicolo-gy,2006,1 (24):2-7.
  • 6Lord AL, Pawliszyn J. Method optimization for analysis of amphetamines in urine by solid phase microextraction [ J ].Anal Chem, 1997, 69: 3899- 3906.
  • 7ACON Laboratories, Inc. ACON(R) one- step drugs of abuse tests [ R]. San Dieago, CA: ACON Laboratories, Inc,2000, 1.
  • 8Supelco, Inc. Instruction for the SupelcoTM Solid phase microextraction fiber holder for manual use ( Catalog No. 5-7330) [R]. Bellefonte, PA: Supelco, Inc, 1995, 1.
  • 9Gronholm M, Lillsunde P. A comparison between on -site immunoassays drug testing devices and laboratory resultsh s[J]. Forensic Sci Int, 2001, 121: 37 -46.
  • 10Huang Z - P, Zhang S - Y. Confirmation of amphetamine,methamphetamine, MDA and MDMA in urine samples using disk solid- phase extraction and gas chromatography -mass spectrometry after immunoassay screening [ J ]. J Chromatogr B, 2003, 792: 293- 245.

共引文献12

同被引文献49

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;