期刊文献+

彩色多普勒超声联合磁共振检测在产前凶险性前置胎盘诊断中的应用 被引量:4

Application of Color Doppler Ultrasonography Combined with Magnetic Resonance Imaging in Prenatal Diagnosis of Dangerous Placenta Previa
下载PDF
导出
摘要 目的探讨彩色多普勒超声联合磁共振检测在产前凶险性前置胎盘诊断中的应用价值。方法选择63例凶险性前置胎盘孕妇作为研究对象,进行磁共振联合彩色多普勒超声检测,比较磁共振检测、磁共振联合彩色多普勒超声检测的诊断结果。结果磁共振联合彩色多普勒超声诊断凶险性前置胎盘的准确率为100.00%,显著高于单独磁共振的77.78%(P <0.05);磁共振联合彩色多普勒超声诊断胎盘附着异常的准确率为100.00%,显著高于单独磁共振的66.67%(P <0.05)。结论彩色多普勒超声联合磁共振诊断凶险型前置胎盘的准确率显著高于单独磁共振诊断,有助于临床医师提前做好充分的手术准备,减少风险的发生。 Objective To explore the application value of color Doppler ultrasonography combined with magnetic resonance imaging in prenatal diagnosis of dangerous placenta previa.Methods 63cases of pregnant women with dangerous placenta previa were selected as research objects.All the cases received color Doppler ultrasonography detection and magnetic resonance imaging detection.The diagnostic results of magnetic resonance imaging detection and color Doppler ultrasonography detection combined with magnetic resonance imaging detection were compared.Results The accuracy rate of color Doppler ultrasonography combined with magnetic resonance imaging in the diagnosis of dangerous placenta previa was 100.00%,significantly higher than 77.78%of single magnetic resonance imaging (P <0.05).The accuracy rate of color Doppler ultrasonography combined with magnetic resonance imaging in the diagnosis of abnormal placenta attachment was 100.00%,significantly higher than 66.67%of single magnetic resonance imaging (P<0.05).Conclusions Color Doppler ultrasonography combined with magnetic resonance imaging has higher accuracy rate than single magnetic resonance imaging in the diagnosis of dangerous placenta previa,which helps clinicians to prepare adequately for surgery in advance and reduces the occurrence of risks.
作者 赵海燕 ZHAO Haiyan(B Ultrasonic Room,Huizhou Third People "s Hospital,Huizhou 516002,China)
出处 《临床医学工程》 2018年第12期1573-1574,共2页 Clinical Medicine & Engineering
基金 惠州市科技计划医疗卫生项目(项目编号:2016Y175)
关键词 彩色多普勒超声 磁共振 凶险性前置胎盘 应用价值 Color Doppler ultrasonography Magnetic resonance imaging Dangerous placenta previa Application value
  • 相关文献

参考文献8

二级参考文献102

  • 1谢幸,苟文丽.妇产科学[M].8版.北京:人民卫生出版社,2013:118-119.
  • 2Yang Q, Wen S W, Oppenheimer L, et al. Association of caesarean delivery for first birth with placenta praevia and placental abruption in second pregnancy[J]. BJOG, 2007, 114 (5):609- 613.
  • 3Rao K P, Belogolovkin V, Yankowitz J, et al. Abnormal placentation: evidence based diagnosis and management of placenta previa, placenta accreta, and vasa previa[J].Obstet Gynecol Surv,2012,67(8) :503-519.
  • 4Bateman B T, Mhyre J M, Callaghan W M, et al. Peripartum hysterectomy in the United States: nationwide 14 year experience[J]. Am J Obstet Gynecol,2012,206(1) :63.
  • 5Brlgitte E. Fluid and blood transfusion management in obstetrics [J]. Eur J Anaesthesiol,2010,27(12) :1031-1035.
  • 6谢幸,苟文丽.妇产科学.北京:人民卫生出版社,2014:384.
  • 7Gurol-Urganci I, Cromwell DA, Edozien LC, et al. Risk of placenta previa in second birth after first birth cesarean section: a population-based study and meta-analysis [J]. BMC Pregnancy Childbirth, 2011,11 : 95.
  • 8Meng X,Xie L,Song W. Comparing the diagnostic value of ultrasound and magnetic resonance imaging for pla- centa accreta:asystematic review and meta-analysis [J]. Ultrasound Med Biol, 2013,39(11) : 1958-1965.
  • 9Allahdini S, Voigt S, Htwei TT. Management of placenla praevia and accreta. J ()bstet Gynaecol, 2011, 31 (1) : 1-6.
  • 10Yang JI, Lim YK, Kim HS, et al. Sonographie findings of pla- cental lacunae and the prediction of adherent placenta in women with placenta previa totalis and prior cesarean section. Ultra- sound Obstet Gynecol, 2006. 28 (2): 178-182.

共引文献418

同被引文献23

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部