为对溶液除湿和冷却除湿在温湿度独立控制系统中的除湿应用特点进行分析,本文以一个具体房间为案例,通过对冷却除湿和溶液除湿系统建立理论模型并进行能耗方面进行了粗略的对比计算,得出结果:将新风处理到同样的状态,溶液除湿比冷却除湿需要更少的冷冻水量,也就是需要制冷量少。综上,除湿系统的选择,需要多方面对比,根据实际情况,选择用恰当的方式。
In order to analyze the characteristics of the dehumidification application of solution dehumidification and cooling dehumidification in the temperature and humidity independent control system,this paper takes a specific room as a case study.Based on the theoretical model of cooling dehumidification and solution dehumidification system and the calculation of energy consumption,the results are obtained:the new wind is treated in the same state,and the solution dehumidification requires less freezing water than cooling dehumidification.That is to say,less refrigeration is required.To sum up,the choice of dehumidification system needs to be compared in many aspects.According to the actual situation, choose the appropriate method.
作者
张金磊
盛肖利
陈永超
Zhang Jinlei;Sheng Xiaoli;Chen Yongchao
出处
《洁净与空调技术》
2018年第4期63-66,共4页
Contamination Control & Air-Conditioning Technology
关键词
温湿度独立控制系统
溶液除湿
冷却除湿
节能分析
Independent control system of temperature and humidity
Dehumidification of solution
Cooling dehumidification
Energy efficiency analysis