摘要
通过1.5 MW变极双绕组风力发电机运转无力问题的分析及解决,得出变极电机双绕组设计中应充分考虑电磁兼容,避免环流产生的结论,同时提出了通过同相线圈组合理串并联消除环流的解决方案。
Through analyzing the weak running of the 1.5MW pole-changing double-winding wind turbine generator and solving this problem,came the conclusion that electromagnetic compatibility should be taken into account to eliminate the circumfluence when designing the double-winding of pole-changing motors.The reasonable series and parallel connection in the same phase winding could be used to eliminate the circumfluence.
作者
王鑫
魏尚武
赵君
WANG Xin;WEI Shangwu;ZHAO Jun(CRRC Yongji Electric Co.,Ltd.)
出处
《电机技术》
2018年第5期30-33,共4页
Electrical Machinery Technology
关键词
变极
双绕组
环流
并联支路数
pole-changing
double-winding
circumfluence