摘要
文章介绍了模块化数据机房的机构组成,通过对传统数据中心和微模块化数据机房的分析比较,总结了微模块化数据机房的快速部署、安全可靠、灵活扩展、绿色节能和智能管理的特点。进一步对比研究了3N或2NUPS和高压直流供电模式在传统数据中心的应用,并提出了“UPS或高压直流+市电”混合供电的新技术模式在未来微模块化数据机房的应用及推广前景。
This paper introduces the structure of modular data centers.Through the analysis and comparison of traditional data centers with micro-modular data centers,the characteristics of micro-modular data centers are summarized,including rapid deployment,high safety and reliability,flexible expansion,green energy saving,and intelligent management. Furthermore,the applications of two power supply modes (3N/2N UPS and HVDC)in traditional data center are compared,and the applications and prospects of a novel hybrid power supply mode with "UPS or HVDC+electric supply"in future micro-modular data centers are discussed.
作者
曹连兵
周莲
王新芳
Cao Lianbing;Zhou Lian;Wang Xinfang(China Mobile Group Design Institute Co.,Ltd.;China Academy of Building Research Co.,Ltd)
出处
《UPS应用》
2019年第1期25-32,共8页
UPS Applications