期刊文献+

燃煤电厂超低排放改造后CEMS设备管理经验浅谈 被引量:3

Discussion on the Management Experience of CEMS Equipment After Ultra Low Emission of Coalfired Power Plants
下载PDF
导出
摘要 结合神华国华锦界能源有限责任公司已经完成烟气超低改造排放机组,根据CEMS设备的测量原理、设备组成,详细阐述了CEMS设备日常和定期维护工作,并结合各级政府环保监督管理部门要求,提出CEMS设备故障的防范措施,故障后应急管理方面经验。 Recently,the Guohua Jinjie energy limited liability company has completed the transformation of ultra low emission gas units. According to the measurement principle and composition of CEMS equipment,this paper made a detailed illustration about CEMS daily and periodic maintenance.In addition,combined with the government requirements of environmental protection supervision, this paper also proposed some CEMS equipment failure prevention measures and emergency management experience after fault.
出处 《自动化博览》 2018年第12期94-97,共4页 Automation Panorama1
关键词 气态污染物 测量 管理 准确性 CEMS Gaseous pollutants Measure Administration Accuracy,CEMS
  • 相关文献