期刊文献+

生物秸秆不燃板房安全防火间距试验

Full-Scale Experimental Evaluation of Fire Safety Distance of Straw Fireproofing Houses
下载PDF
导出
摘要 对新型生物秸秆不燃板材搭建的活动板房进行了全尺寸火灾试验.通过测量板房室内外的温度数据及室外不同距离处的热辐射强度数据,分析生物秸秆不燃板房的火灾蔓延特性.通过回归分析建立生物秸秆不燃板房的室外最大热辐射强度与距离的函数关系式,确定生物秸秆不燃板房的安全防火间距.结果表明,秸秆防火板材的阻燃性能对于抑制火灾蔓延有重要作用;采用生物秸秆不燃材料的活动板房,临栋的安全防火间距建议为2.34m;对于极端大风天气,生物秸秆不燃板房临栋的安全防火间距建议为2.51m. Full-scale fire experiments were conducted to study the fire safety distance of novel straw fireproofing houses. Room temperatures, ambient temperatures and thermal radiation intensities were measured to analyze the behavior of straw fireproofing houses during the fire.The formula for the maximum outdoor thermal radiation intensities of straw fireproofing house at various distances was obtained by regression analysis,and this equation could be used to calculate the fire safety distance.It is found that the fire spread is significantly restricted by using straw fireproofing material.For the straw fireproofing houses,the fire safety distance is suggested to be 2.34 m.Furthermore,for the straw fireproofing houses under severe weather conditions with strong wind,the fire safety distance is suggested to be2.51 m.
作者 王厚华 季文慧 宋晓勇 李伟 WANG Houhua;JI Wenhui;SONG Xiaoyong;LI Wei(Faculty of Urban Construction and Environment Engineering, Chongqing University,Chongqing 400045,China;Sichuan General Fire Brigade,Chengdu 610036,China;Vitalong Fire Safety Group Co.,Ltd.,Chengdu 611731,China)
出处 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2018年第12期1653-1658,共6页 Journal of Tongji University:Natural Science
基金 国家自然科学基金(51578086)
关键词 活动板房 防灾 防火间距 秸秆 temporary house disaster prevention fire safety distance straw
  • 相关文献

参考文献5

二级参考文献29

  • 1周庆.网格划分对FDS火灾模拟结果的影响分析[J].安全,2011,32(8):8-11. 被引量:19
  • 2全国人民代表大会常务委员会.中华人民共和国防震减灾法[s].
  • 3国务院令第526号.汶川地震灾后恢复重建条例[s].
  • 4国发[2008]22号.国务院关于做好汶川地震灾后恢复重建工作的指导意见[S].
  • 5国发[2008]31号.国务院关于印发汶川地震灾后恢复重建总体规划的通知[S].
  • 6住房和城乡建设部.地震灾区过渡安置房建设技术导则[s].
  • 7四川省“5·12”抗震救灾指挥部.四川省地震灾区过渡安置点建设消防技术措施[S].
  • 8四川省"5·12"抗震救灾指挥部.四川省地震灾民安置点消防安全管理规定[s].
  • 9Griffin G J, Bicknell A, Bradbury G, et al. The effect of construction method on the fire behavior of sandwich panels with expanded polystyrene (EPS) cores in room fire tests [J]. Journal of Fire Sciences, 2006, 24 (4) : 275-294.
  • 10Oleszkiewicz I. Fire exposure to exterior walls and flame spread in combustible cladding[J]. Fire Technology, 1990, 26(4): 357-375.

共引文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部