摘要
建立了采用阀切换和预分离柱的气相色谱法测定汽油中甲缩醛、乙酸仲丁酯、碳酸二甲酯含量的方法。结果表明,当柱温为60℃、阀切换时间0. 45 min时,各目标物含量在0. 2%~10. 0%范围内,线性相关系数均大于0. 9995。方法的加标回收率均90%~110%,相对标准偏差均小于1%,3种目标化合物的检出限分别为:甲缩醛0. 03%、碳酸二甲酯0. 02%、乙酸仲丁酯0. 3%。
For the detection of illegal additions in gasoline,such as methylal,dimethyl carbonate and sec-butyl acetate,a test method was developed for the analysis of methylal,dimethyl carbonate and sec-butyl acetate in gasoline using a gas chromatography(GC)with valve switching and pre-column.The results showed that when the column temperature was 60℃ and the switching time was 0.45 min,the linear correlation coefficient of each target compound is higher than 0.9995 in the range of 0.2%to 10.0%.The method has recoveries of 90%-110% and relative standard deviations of less than1.0%.The detection limits of methylal dimethyl carbonate and sec-butyl acetate are 0.03%,0.02%,0.3%,respectively.
作者
戎慧敏
邓可
薛秋红
周龙龙
白洁
王静静
RONG Hui-min;DENG Ke;XUE Qiu-hong;ZHOU Long-long;BAI Jie;WANG Jing-jing(Insititute of Environment Science and engigeering Ocean University of China,Qingdao 266100;Teehnique Center of Shandong Exit-Entry Inspection and Quarantine Bureau of China, Qingdao 266500)
出处
《分析试验室》
CAS
CSCD
北大核心
2019年第1期47-51,共5页
Chinese Journal of Analysis Laboratory
基金
山东出入境检验检疫局科研项目(SK2016011
SK2016041)资助
关键词
气相色谱
汽油
甲缩醛
碳酸二甲酯
乙酸仲丁酯
预分离柱
Gas chromatography
Gasoline
Methylal
Dimethyl carbonate
Sec-butyl acetate
Pre-column.