摘要 为研究污秽对绝缘子串电压分布及红外热像法测零值绝缘子的影响,以110 kV绝缘子串为例,采用有限元分析方法对不同污秽条件下含零值及正常绝缘子串的电压分布进行了多组仿真对比试验。结果表明:零值绝缘子位于两端比位于中部对绝缘子串电压分布的影响更大;随着等值盐密的增大,绝缘子串电压分布趋于均匀,零值绝缘子负温升特征的显著性有所下降;绝缘子串下表面覆污时的电压分布比上表面覆污时更均匀;当两端污秽度大时,绝缘子串的分布电压在中部最高。 In order to investigate the influence of pollution on the voltage distribution of insulator strings and the decection of faulty insulators by infrared imaging method, the voltage distribution of 110 kV insulator strings with and without faulty insulator was simulated and compared by finite element analysis under different content of pollution. The results show that the effect of faulty insulator at the end of insulator string on the voltage distribution is bigger than that in the middle. With the increase of the equivalent salt deposit density, the voltage distribution of insulator string tends to be uniform, and the significance of negative temperature rise of faulty insulator decreases. When the lower surface of insulator string is polluted, the voltage distribution of insulator string is more uniform. When the pollution is heavy at both ends of insulator string, the middle of insulator string has the highest voltage.
作者 王欣 李凯迪 陈凡辉 钱平 尹骏刚 周友维 姚建刚 WANG Xin;LI Kaidi;CHEN Fanhui;QIAN Ping;YIN Jungang;ZHOU Youwei;YAO Jiangang(College of Electrical and Information Engineering,Hunan University,Changsha 410082,China;State Grid Zhejiang Electric Power Company,Hangzhou 310007,China)
出处 《绝缘材料》 CAS 北大核心 2019年第1期84-90,共7页 Insulating Materials
基金 浙江省电力有限公司科研基金项目(SGZJJX00BYJS1700242)
关键词 覆污绝缘子 电位分布 有限元法 三维模型 不均匀性 contaminated insulators potential distribution finite element method three-dimensional model non-uniformity
  • 相关文献

参考文献14

二级参考文献145

共引文献263

同被引文献109

引证文献7

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部