期刊文献+

Evaluation of dynamic stereopsis in intermittent exotropia patients 被引量:4

Evaluation of dynamic stereopsis in intermittent exotropia patients
下载PDF
导出
摘要 AIM: To delineate the characteristics of the dynamic stereopsis test and analyze related parameters in intermittent exotropia [X(T)] patients. METHODS: Fifty-seven X(T) patients and 55 normal subjects were enrolled in this study. The normal and X(T) groups were used to test the reproducibility and reliability of the dynamic stereopsis test, and Bangerter filters with densities of 0.2 were then used to simulate suppression to test for traditional and dynamic stereopsis. In the X(T) group, the measurements included 1) dynamic stereopsis test comprising three parts: motion+disparity, motion only and disparity only; 2) ocular deviation angle; 3) Bagolini striated lens test; 4) disease course; and 5) Titmus stereopsis test. RESULTS: The test-retest reliability of the dynamic stereopsis method was 0.901 in the normal and X(T) groups, and none of the X(T) patients were able to pass the static and dynamic stereopsis tests after using the 0.2 Bangerter filter. The accuracy rate was greater than 80% in the normal group and 31.81%, 36.36%, and 45.45% for the motion+disparity, motion-only and disparityonly components of the traditional test for X(T) patients diagnosed with stereoblindness via traditional tests,respectively. Patients with a long disease course(>1 y) had worse dynamic stereopsis than those with a short disease course(<1 y; P<0.05, Chi-square test). The deviation angle was not correlated with the motion+disparity, disparityonly, or the motion-only test components(all P>0.05, Chisquare test). CONCLUSION: Dynamic stereopsis is preserved in certain X(T) patients diagnosed with stereoblindness via traditional tests. A long disease course was shown to be a negative factor for dynamic stereopsis in X(T) patients which might be associated with worse progression, and provide good references clinically. AIM: To delineate the characteristics of the dynamic stereopsis test and analyze related parameters in intermittent exotropia [X(T)] patients.METHODS: Fifty-seven X(T) patients and 55 normal subjects were enrolled in this study. The normal and X(T) groups were used to test the reproducibility and reliability of the dynamic stereopsis test, and Bangerter filters with densities of 0.2 were then used to simulate suppression to test for traditional and dynamic stereopsis. In the X(T) group, the measurements included 1) dynamic stereopsis test comprising three parts: motion+disparity, motion only and disparity only; 2) ocular deviation angle; 3) Bagolini striated lens test; 4) disease course; and 5) Titmus stereopsis test. RESULTS: The test-retest reliability of the dynamic stereopsis method was 0.901 in the normal and X(T) groups, and none of the X(T) patients were able to pass the static and dynamic stereopsis tests after using the 0.2 Bangerter filter. The accuracy rate was greater than 80% in the normal group and 31.81%, 36.36%, and 45.45% for the motion+disparity, motion-only and disparityonly components of the traditional test for X(T) patients diagnosed with stereoblindness via traditional tests,respectively. Patients with a long disease course(>1 y) had worse dynamic stereopsis than those with a short disease course(<1 y; P<0.05, Chi-square test). The deviation angle was not correlated with the motion+disparity, disparityonly, or the motion-only test components(all P>0.05, Chisquare test). CONCLUSION: Dynamic stereopsis is preserved in certain X(T) patients diagnosed with stereoblindness via traditional tests. A long disease course was shown to be a negative factor for dynamic stereopsis in X(T) patients which might be associated with worse progression, and provide good references clinically.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第1期83-88,共6页 国际眼科杂志(英文版)
基金 Supported by National Natural Science Foundation of China (No.81600761) the Natural Science Foundation Team Projectof Guangdong Province (No.2015A030312016)
关键词 MOTION DISPARITY INTERMITTENT EXOTROPIA motion disparity intermittent exotropia
  • 相关文献

同被引文献41

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部