合理应用X射线检查优化辐射剂量 被引量:21

To optimize radiation dose by reasonable application of X-ray examination
原文传递
导出
摘要 X射线的影像学检查是现代化精准医疗中的重要环节,在诊治疾病和判断疾病转归及手术方案制定中发挥着不可替代的作用。随着数字X射线和CT检查的广泛应用,重复的和过度的X射线检查时有发生,使受检者接受了过多的或额外辐射剂量,引起辐射损伤。如何优化辐射剂量,达到既满足疾病的诊断,又能降低受检者的辐射损伤,是研究者和设备研发者关注的重要课题。以致X射线的辐射损伤引起了政府、社会、受检者和X射线检查工作者的高度关注。本文探讨了降低辐射剂量的方法,评述其进展。 X-ray examination is an important part of modern precision medicine,and plays an irreplaceable role in the diagnosis and evaluation of disease outcomes as well as the surgical planning.With the widespread use of digital radiology and CT examinations,repeated and excessive X-ray examinations occur that cause the subject to receive excessive or additional radiation doses which cause radiation damage.How to optimize the radiation dose to meet the diagnosis of the disease and reduce the radiation damage of the subject is an important topic for researchers and equipment developers.As a result,X-ray radiation damage has attracted the attention of governments,society,subjects and X-ray inspection workers.This article explores ways to reduce radiation dose and reviews its progress.
作者 王淼 肖志清 王艳强 郭晗 冀书颖 余建明 Wang Miao;Xiao Zhiqing;Wang Yanqiang;Guo Han;Ji Shuying;Yu Jianming(The Second Hospital of Hebei Medical University,Shijiazhuang 050000,China;Union Hospital,Tongfi Medical College,Huazhong University of Science and Technology,Wuhan 430000,China)
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2019年第1期1-5,共5页 Chinese Journal of Radiological Medicine and Protection
关键词 数字X射线 X射线计算机断层摄影 辐射损伤 低剂量 Digital radiology Computed tomography Radiation damage Low dose
  • 相关文献

参考文献7

二级参考文献65

  • 1UNSCEAR. Sources and effects of ionizing radiation: UNSCEAR 2000 report volume I . New York: UN, 2000, Annex D: Medical radiation exposure.
  • 2UNSCEAR. Medical radiation exposure. 2008.
  • 3国际放射防护委员会.岳保荣,韩艳清,译.尉可道,校.计算机体层摄影中患者剂量控制:国际放射防护委员会第87号出版物.北京:人民卫生出版社,2005.
  • 4ICRP. The 2007 recommendation of international commission on radiological protection. ICRP publication 103. Ann ICRP, 2007, 37(2 4):1-332.
  • 5国家质量监督检验检疫总局.GB188712002.电离辐射防护与辐射源安全基本标准北京:中国标准出版社,2002.
  • 6CEC. European guidelines quality criteria for computed tomography. Report EUR 16262. Brussels, Belgium: European Lommlssion, 1999.
  • 7Shrirrlpton PC, Wall BF. Reference dose for pediatric computed tomography. Radiat Prot Dosim, 2000,90 : 249-252.
  • 8尉可道.CT剂量的测量方法的新进展,对CTD1100表述的质疑[J].世界医疗器械,2008,14(11):9-12.
  • 9Nagel HD. Radiation exposure in computed tomography: funda mentals, influencing parameters, dose assessment, optimisation scanner data, terminology. 4th ed. Hamburg: CTB Publications 2002.
  • 10ICRP. Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann ICRP, 2007, 37 (1):1-79.

共引文献152

同被引文献212

引证文献21

二级引证文献60

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部